hi, i've just received a U2713H monitor
And to my disappointment [:(], turning on the monitor shows color shift from left cyan to right magenta.
Going thru the Calibration Factory Report 5x5 zones for the Color Uniformity Delta E show as below
Red = Zone , Underlined = center of screen.
01) 0.15 02) 0.31 03) 0.26 04) 0.79 05) 0.65
06) 0.13 07) 0.13 08) 0.15 09) 0.80 10) 0.49
11) 0.13 12) 0.20 13) 0.00 14) 0.88 15) 0.95
16) 0.07 17) 0.23 18) 0.37 19) 0.41 20) 0.99
21) 0.27 22) 0.27 23) 0.59 24) 0.53 25) 0.94
These reading fits what i am seeing on the display.
I find the color shift is way too off from the center especially on the right readings rendering 40% of the screen unusable.
I will do a test with my X-rite i1Pro colorimeter and update the result again.
My Question is, am i able to request for a exchange unit of the U2713H based on this issue.
Any advise would be greatly appreciated.